Fast heating tube test of MCX-8100 EMTAP 41 Test
About the publication
ISBN
9788246429274
Size
4.1 MB
Language
English
The EMTAP 41 fast heating tube test has been carried out during STANAG 4170 qualification of
MCX-8100. Seven tubes have been tested and all open up by a burning or degree 1 reaction
with no fragmentation. The recovered tubes may be divided into two groups. Four tubes have
one longitudinal crack in the center of the body. These reacted after 124+5 seconds at an outer
tube surface temperature of 500+33oC. The three remaining tubes, still in one piece, have two
or more longitudinal cracks in the body. For these tubes the time to reaction is 154+12 seconds
with an outer tube surface temperature of 390+25oC.
MCX-8100 gives a degree 1 or burn reaction for all seven tested tubes in the fast heating test.
This shows a mild reaction of the MCX-8100 composition when exposed to the fast heating
threat. For munitions filled with MCX-8100 the possibility to achieve IM properties should be
good when exposed to thermal threats.